Your trust Is Our Responsibility

Hydrostatic Pressure Testing Machine

Inspire Plastotherm hydro-static pressure testing machine is designed specifically for testing HDPE, PVC, PPR, Lateral pipes as per IS 4985, IS 4984, IS 12786, IS 14333, IS 14151, IS 15328, IS 15801, EN 921:1994, ASTM D 1785 and other relevant standards. Hydro-static pressure testing machine is used to maintain the required pressure in pipes.

TECHNICAL DETAILS

ModelPressure StationsVersionAccumulator Unit.Power Req.
HYDRO-105-IP05DigitalYes1 Phase 220/230 V Ac 50Hz.
HYDRO-104-IP04DigitalYes1 Phase 220/230 V Ac 50Hz.
HYDRO-103-IP03DigitalYes1 Phase 220/230 V Ac 50Hz.
HYDRO-102-IP02DigitalYes1 Phase 220/230 V Ac 50Hz.
HYDRO-101-IP01DigitalYes1 Phase 220/230 V Ac 50Hz.

FEATURES

  • Standard equipment includes versatile microprocessor based controller with high performance to price ratio. This is a single chip micro-controller based controller designed for 4-20 mA inputs. Four user-friendly key operated instrument, where keys are used for programming of pressure display unit of each channel.
  • Separate versatile microprocessor based controller for each station with high accuracy pressure control up to 0.10 bar.
  • Option of one to three pressure outlets with each station, or as per customer requirement.
  • User friendly Windows XP/7/8.1 based software suitable up to 32 pressure stations and 08 temperature stations in software. All the stations can be operated from single bar graph window from computer display and all pressure control parameter can be set by few selected mouse clicks.
  • PC connectivity is not required for entire test duration with machine. After completion of test, data can be downloaded from machine to PC. Machine display micro controller is with inbuilt memory card, suitable up to 3000 data storage.
  • Facility of report generation is available in two formats (1) in software format & (2) in Microsoft excel with graph and test data.
  • Option of two type of booster for accumulator (1) motorize pump system which requires only water inlet & (2) pneumatic pump system which requires air and water inlet to generate pressure.